HYDRAULIC GENERATOR REPLACEMENT
HYDRAULIC GENERATOR REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 4 Page Navigation
  171    172    173    174    175  176  177    178    179    180    181  
img
DRAFT
TM 5-4210-249-13&P-4
0592
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00390A
4.
Disconnect two connectors (7).
5.
Remove four locknuts (8), eight washers (9), four screws (10), and air conditioning fan assembly (11) from
hydraulic generator (12). Discard locknuts.
NOTE
Note position of hydraulic generator cover prior to removal to ensure proper installation.
6.
Remove ten screws (13), lockwashers (14), washers (15), and hydraulic generator cover (16) from hydraulic
generator. Discard lockwashers.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -