DRAFT
TM 5-4210-249-13&P-4
FIELD LEVEL MAINTENANCE
PUMP COOLER (DUMP-TO-GROUND) VALVE REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
Equipment Conditions
Materials/Parts
Water pump engine OFF (WP 0022)
Compound, Sealing, Pipe Thread
Engine OFF (TM 9-2320-347-10)
Wheels chocked (TM 9-2320-347-10)
Air system drained (TM 9-2320-347-10)
Lockwasher (4)
Water system drained (WP 0041)
Lockwasher (2)
REMOVAL
TFFT00150
NOTE
Tag and mark air lines and water lines prior to removal to ensure proper installation.
Air lines on pump cooler (dump-to-ground) valve remain attached to elbows.
1.
Remove two air lines (1) and (2) and elbows (3) and (4) from pump cooler (dump-to-ground) valve (5).
2.
Remove two fittings (6) and (7) and water lines (8) and (9) from elbows (10) and (11).
0578-1