PRESSURE REDUCING VALVE DRIVER PRE-CONNECT "A" REPLACEMENT - Continued
PRESSURE REDUCING VALVE DRIVER PRE-CONNECT "A" REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  919    920    921    922    923  924  925    926    927    928    929  
img
. .
DRAFT
TM 5-4210-249-13&P-3
0491
INSTALLATION
CAUTION
Pressure reducing valve must be open all the way before installing hose clamp.
Failure to comply will not allow correct flow of water.
NOTE
Install valve, pipes, and elbows as noted prior to removal.
1.
Install hose clamp (15) on pressure reducing valve (12).
2.
Install two pipes (14) and (13) on pressure reducing valve (12) (WP 0489).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
3.
Apply sealing compound to threads of elbow (9).
4.
Install elbow (9) on pipe (13).
5.
Install pressure reducing valve (12) and two couplings (11) and (10) on vehicle (WP 0483).
6.
Install hose (8) on elbow (9).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -