DRAFT
TM 5-4210-249-13&P-3
0486
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT0784
9.
Remove tee (21) and nipple (22) from adapter (23).
10. Remove pipe (10) from adapter (23).
NOTE
Note position of adapters on valve prior to replacement to ensure proper installation.
11. Remove four screws (24) and adapter (23) from valve (20).
12. Remove four screws (25) and adapter (26) from valve (20).
13. Remove elbow (27) from fitting (28).
14. Remove fitting (28), elbow (3), and nipple (22) from tee (21).
END OF TASK
INSTALLATION
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
NOTE
Install cable ties as required.
1.
Apply sealing compound to threads of nipple (22), fitting (28), and two elbows (3) and (27).
0486-3