ROOF, BUMPER, AND PUMP COOLER DUMP-TO-GROUND JUNCTION BOX REPLACEMENT - Continued
ROOF, BUMPER, AND PUMP COOLER DUMP-TO-GROUND JUNCTION BOX REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  423    424    425    426    427  428  429    430    431    432    433  
img
DRAFT
TM 5-4210-249-13&P-3
0423
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT04640
8.
Remove fitting (5), grommet (19), backing washer (20), and collar (21) from cable (22).
END OF TASK
INSTALLATION
1.
Install collar (21), backing washer (20), grommet (19), and fitting (5) on cable (22).
2.
Install grommet (18) on junction box (6).
3.
Install two grommets (17) on junction box (6).
4.
Install terminal strip (3) on junction box (6) with two screws (16), washers (15), and locknuts (14).
5.
Position wire harness (13) in junction box (6).
6.
Install five wires 4055 (12), 2837 (11), 4037 (10), 1640 (9), and 2848 (8) on terminal strip (3) with five
screws (7).