• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
PUMP OPERATOR'S PANEL ELECTRIC VALVE CONTROL/METER REPLACEMENT - Continued
PUMP OPERATOR'S PANEL ELECTRIC VALVE CONTROL REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  411    412    413    414    415  416  417    418    419    420    421  
img
. .
DRAFT
TM 5-4210-249-13&P-3
0418
FIELD LEVEL MAINTENANCE
PUMP OPERATOR'S PANEL ELECTRIC VALVE CONTROL REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
WP 0615, Fig. 56
(WP 0622, Item 27)
Equipment Conditions
Materials/Parts
Batteries disconnected (TM 9-2320-325-14&P)
Tags, Identification (WP 0625, Item 51)
Pump panel housing opened (WP 0325)
REMOVAL
TFFT00348
NOTE
Driver main inlet and passenger side aux. inlet electric valve controls are equipped with
two connectors. Tank fill and re-circulating line electric valve control is equipped with
three connectors. Tank fill and re-circulating line electric valve control shown.
Tag and mark connectors prior to removal to ensure proper installation.
1.
Disconnect three connectors (1).
2.
Remove four screws (2), washers (3), and electric valve control (4) from pump panel (5).
END OF TASK