DRAFT
TM 5-4210-249-13&P-3
FIELD LEVEL MAINTENANCE
BATTERY EQUALIZER REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
WP 0615, Fig. 74
(WP 0622, Item 27)
Equipment Conditions
Materials/Parts
Water pump engine OFF (WP 0022)
Adhesive, RTV732 (WP 0625, Item 2)
Batteries disconnected (TM 9-2320-325-14&P)
Tags, Identification (WP 0625, Item 51)
Locknut (1)
Locknut (1)
Locknut (1)
REMOVAL
TFFT02145
CAUTION
To avoid reverse polarity damage when removing equalizer battery cables, always
remove equalizer ground cable first. Failure to comply may result in damage to
equipment.
NOTE
Tag and mark wires prior to removal to ensure proper installation.
1.
Remove locknut (1) and ground cable (2) from terminal (3). Discard locknut.
2.
Remove locknut (4) and cable (5) from terminal (6). Discard locknut.