BATTERY EQUALIZER REPLACEMENT- Continued
BATTERIES, TERMINAL, AND CABLE REPLACEMENT

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  256    257    258    259    260  261  262    263    264    265    266  
img
DRAFT
TM 5-4210-249-13&P-3
0367
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT02145
4.
Install cable (5) on terminal (6) with locknut (4).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
5.
Apply electrical sealant to three terminals (3), (6), and (11) and locknuts (1), (4), and (7).
END OF TASK
FOLLOW-ON MAINTENANCE
Connect batteries (TM 9-2320-325-14&P)
END OF TASK
END OF WORK PACKAGE
0367-3/(4 blank)