PUMP OPERATOR'S PANEL PRIMER SWITCH REPLACEMENT
PUMP OPERATOR'S PANEL REPLACEMENT

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  135    136    137    138    139  140  141    142    143    144    145  
img
.
DRAFT
TM 5-4210-249-13&P-3
0333
INSTALLATION
TFFT00363
1.
Install/adjust nut (8) on primer switch (4).
2.
Install primer switch (4) on pump operator's panel (7) with guard (6) and cover (5).
3.
Install two wires (3) on primer switch (4) with two washers (2) and screws (1).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
4.
Apply electrical sealant to ends of two wires (3) and screws (1).
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Close pump operator's panel housing (WP 0325)
2.
Connect batteries (TM 9-2320-325-14&P)
END OF TASK
END OF WORK PACKAGE