DRAFT
TM 5-4210-249-13&P-3
0311
PANEL B REMOVAL
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT02758
CAUTION
When performing Step (2), pull instrument panel B forward only enough to access
wires. Failure to comply may result in damage to equipment.
1.
Remove siren control (1) from instrument panel B (2) (WP 0341).
2.
Remove five screws (3) and instrument panel B (2) from instrument assembly frame (4).
3.
Remove seven toggle switches (5) from instrument panel B (2) (WP 0315).
4.
Remove six cab panel indicators (6) from instrument panel B (2) (WP 0313).
5.
Remove three water and foam level gauges (7) from instrument panel B (2) (WP 0316).
6.
Remove pump discharge pressure gauge (8) from instrument panel B (2) (WP 0316).
7.
Remove foam tank selector switch (9) from instrument panel B (2) (WP 0308).
8.
Remove two foam tank selector switch indicators (10) from instrument panel B (2) (WP 0306).
END OF TASK
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0311-8