DRAFT
TM 5-4210-249-13&P-2
0293
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT01591A
NOTE
Fresh air hose must be moved in order to remove screws at front of fill port extension.
3.
Loosen clamp (5) and remove fresh air hose (6) from elbow (7).
4.
Remove 20 screws (8), washers (9), and fill port extension (4) from water tank (10).
5.
Remove two screws (11) and cover (1) from hinge (12).
6.
Remove two locknuts (13), screws (14), and hinge (12) from fill port extension (4).
7.
Remove four screws (15) and latch (16) from fill port extension (4).
8.
Remove three screws (17) and latch catch (18) from cover (1).
END OF TASK
INSTALLATION
1.
Install latch catch (18) on cover (1) with three screws (17).
2.
Install latch (16) on fill port extension (4) with four screws (15).
3.
Install hinge (12) on fill port extension (4) with two locknuts (13) and screws (14).
4.
Install cover (1) on hinge (12) with two screws (11).
0293-2