DRAFT
TM 5-4210-249-13&P-2
0288
INSTALLATION
TFFT01055
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
CAUTION
Use sealing compound sparingly only on pipe threads. Do not apply compound to
hose connections. Damage to equipment may result.
NOTE
Install cable ties as required.
1.
Apply sealing compound on threads of three elbows (8), (11), and (12), six fittings (19), (20), (21), (22), (23),
and (24), and plug (30).
2.
Install three elbows (8), (11), and (12), six fittings (19), (20), (21), (22), (23), and (24), and plug (30) on control
valve manifold (28).
3.
Install control valve manifold (28) on base (29) with two screws (27), washers (26), and locknuts (25).
4.
Install six air lines (13), (14), (15), (16), (17), and (18) on fittings (19), (20), (21), (22), (23), and (24).
0288-4