FOAM SYSTEM EDUCTOR VALVE REPLACEMENT
FOAM SYSTEM FLOW CONTROL MANIFOLD REPLACEMENT

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  1279    1280    1281    1282    1283  1284  1285    1286    1287    1288    1289  
img
DRAFT
TM 5-4210-249-13&P-2
0287
INSTALLATION
TFFT00083
1.
Install two couplings (6) and (7) and foam system eductor valve (5) on vehicle (WP 0483).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
CAUTION
Use sealing compound sparingly only on pipe threads. Do not apply compound to
hose connections. Damage to equipment may result.
2.
Apply sealing compound to two elbows (3) and (4).
3.
Install two air lines (1) and (2) and elbows (3) and (4) on foam system eductor valve (5).
END OF TASK
FOLLOW-ON MAINTENANCE
Close pump house panel A (WP 0539)
END OF TASK
END OF WORK PACKAGE