DRAFT
TM 5-4210-249-13&P-2
FIELD LEVEL MAINTENANCE
FOAM LEVEL PROBE REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
WP 0615, Fig. 51, 136
(WP 0622, Item 27)
Equipment Conditions
Materials/Parts
Water pump engine OFF (WP 0022)
Shrink, Heat (WP 0625, Item 48)
Batteries disconnected (TM 9-2320-325-14&P)
Ties, Cable, Plastic (WP 0625, Item 58)
REMOVAL
TFFT01082
NOTE
Both foam probes are removed the same way.
Remove cable ties as required.
Perform Step (1) to remove foam level probe cover.
1.
Remove four screws (1), washers (2), and cover (3) from hose bed (4).
2.
Remove heat shrink (5) and disconnect connector (6).
3.
Remove four screws (7), foam level probe (8), and gasket (9) from tank (10).
END OF TASK
0281-1