FLUSH CHECK VALVE REPLACEMENT - Continued
FOAM LEVEL PROBE REPLACEMENT

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  1267    1268    1269    1270    1271  1272  1273    1274    1275    1276    1277  
img
DRAFT
TM 5-4210-249-13&P-2
0280
INSTALLATION
TFFT00902
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
CAUTION
Use sealing compound sparingly only on pipe threads. Do not apply compound to
hose connections. Damage to equipment may result.
1.
Install elbow (4) and pipe (5) on flush check valve (3) (WP 0489).
2.
Install flush check valve (3) and two couplings (1) and (2) on vehicle (WP 0483).
END OF TASK
FOLLOW-ON MAINTENANCE
Close pump house panel A (WP 0539)
END OF TASK
END OF WORK PACKAGE
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -