PRESSURE GOVERNOR ADJUSTMENT - Continued
PRESSURE GOVERNOR ADJUSTMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  826    827    828    829    830  831  832    833    834    835    836  
img
DRAFT
TM 5-4210-249-13&P-2
0193
NOTE
Adjustments to pressure governor controls should be made in small increments.
Note value of GAIN.
4.
Press DEC (decrease) switch (6), and decrease GAIN by one count.
5.
Press PRESET switch (3).
6.
Press IDLE switch (2) to exit program.
END OF TASK
PRESSURE GOVERNOR SENSITIVITY ADJUSTMENT
1.
With MODE displayed in MESSAGE CENTER (1), press and hold IDLE switch (2) and PRESET switch (3),
and press MODE switch (4).
2.
Release IDLE switch (2) and PRESET switch (3), and press MODE switch (4) until SENSITIVITY is displayed
in MESSAGE CENTER (1).
3.
Press INC (increase) switch (5) to select SENSITIVITY.
NOTE
Adjustments to pressure governor controls should be made in small increments.
Note value of SENSITIVITY.
4.
Using INC (increase) switch (5), increase SENSITIVITY by one count.
5.
Press PRESET switch (3).
6.
Press IDLE switch (2) to exit program.
END OF TASK
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -