HYDRAULIC GENERATOR COMPENSATOR ADJUSTMENT
PRESSURE GOVERNOR ADJUSTMENT

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  823    824    825    826    827  828  829    830    831    832    833  
img
DRAFT
TM 5-4210-249-13&P-2
0192
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00499
CAUTION
Prior to adjustment, ensure generator system is unloaded and hydraulic pump is
within rpm operating parameters. Failure to comply may cause damage to
equipment.
3.
Unload generator system (WP 0021).
4.
Remove cap (2) from hydraulic compensator (3).
5.
Loosen jamnut (4).
6.
Holding jamnut (4), adjust adjusting screw (5) to proper setting.
7.
Holding adjusting screw (5), tighten jamnut (4).
8.
Install cap (2) from hydraulic compensator (3).
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE