HYDRAULIC GENERATOR DOES NOT OPERATE PROPERLY
HYDRAULIC GENERATOR DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  555    556    557    558    559  560  561    562    563    564    565  
img
.
DRAFT
TM 5-4210-249-13&P-2
0171
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04510
NOTE
Hydraulic generator provides power for the following components: air conditioner, cord
reel, receptacles, extendable floodlights, 120-volt receptacles, water heaters, heat trace,
and reciprocating saw battery charger receptacles. If any of these components operate,
troubleshoot the component that does not operate before performing this procedure.
Step 1.
Turn battery disconnect switch to ON position (WP 0007). Start hydraulic generator
(WP 0021). Check if GEN PTO ENGAGED indicator illuminates.
If GEN PTO ENGAGED indicator does not illuminate, troubleshoot GEN
PTO ENGAGE Indicator Does Not Illuminate (Cab) (WP 0139).