CORD REEL REWIND CONTROL DOES NOT OPERATE
CORD REEL REWIND CONTROL DOES NOT OPERATE

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  544    545    546    547    548  549  550    551    552    553    554  
img
DRAFT
TM 5-4210-249-13&P-2
0169
TFFT04209
Step 5.
Turn battery disconnect switch to OFF position (WP 0007). Remove cord reel rewind
motor power wire from cord reel rewind solenoid (WP 0383). Turn battery disconnect
switch to ON position (WP 0007). While an assistant pushes and holds CORD REEL
REWIND button (WP 0004), check for 22 to 28 VDC between cord reel rewind motor
power wire at cord reel rewind solenoid terminal and a known good ground. Install cord
reel rewind motor power wire on cord reel rewind solenoid (WP 0383).
If 22 to 28 VDC are not present, go to Step 7.
Step 6.
Turn battery disconnect switch to OFF position (WP 0007). Check for continuity across
cord reel rewind motor ground wire (black) from cord reel solenoid to a known good
ground.
a.
If there is continuity, replace cord reel motor (WP 0376).
b.
If there is no continuity, repair cord reel ground wire from chassis
ground terminal block to ground stud (TM 9-2320-325-14&P), or
replace cord reel ground wire (WP 0393).
0169-4