CORD REEL REWIND CONTROL DOES NOT OPERATE
CORD REEL REWIND CONTROL DOES NOT OPERATE

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  546    547    548    549    550  551  552    553    554    555    556  
img
DRAFT
TM 5-4210-249-13&P-2
0169
TFFT04214
Step 9.
Install cord reel inline fuse (WP 0394). Check for continuity across black wire from
CORD REEL REWIND button terminal to cord reel rewind solenoid terminal.
If there is no continuity, repair black wire if
repairable (TM 9-2320-325-14&P), or replace black
wire (TM 9-2320-325-14&P).
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 10.
Turn battery disconnect switch to ON position (WP 0007). Check for 22 to 28 VDC
between white wire at CORD REEL REWIND button terminal and a known good
ground.
a.
If 22 to 28 VDC are present, replace CORD REEL REWIND
button (WP 0380).
b.
If 22 to 28 VDC are not present, repair white wire if repairable
(TM 9-2320-325-14&P), or replace white wire (TM 9-2320-325-14&P).