DRAFT
TM 5-4210-249-13&P-2
0168
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04297
Step 38.
Disconnect main wire harness from non-operating side clearance/turn light
connector (WP 0343). With a test lead set, check for 22 to 28 VDC between wire H012
(white) at main wire harness side clearance/turn light connector, terminal 2 and a known
good ground.
If 22 to 28 VDC are not present, repair wire H012 in main wire harness
(TM 9-2320-325-14&P), or replace main wire harness (WP 0455).
Step 39.
Turn Service Drive Lights Off (TM 9-2320-347-10). Turn battery disconnect switch to
OFF position (WP 0007). With a test lead set, check for continuity across main wire
harness wire 1640 (black) from main wire harness side clearance/turn light connector,
terminal 1 and a known good ground.
a.
If there is continuity, replace non-operating side clearance/turn
light (WP 0343).
b.
If there is no continuity, repair wire 1640 in main wire harness if
repairable (TM 9-2320-325-14&P), or replace main wire harness
(WP 0455).
Step 40.
Remove one non-operating side clearance/turn light (WP 0343). With a test lead set,
check for 22 to 28 VDC between wire H012 (white) at main wire harness side
clearance/turn light connector, terminal 2 and a known good ground.
If 22 to 28 VDC are present, repair wire 1640 if repairable
(TM 9-2320-325-14&P), or replace main wire harness (WP 0455).
0168-24