DRAFT
TM 5-4210-249-13&P-2
0155
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04400
Step 16.
Put EMERG MASTER and SIDE WARNING switches to off position (WP 0004). Turn
Service Drive Lights Off (TM 9-2320-347-10). Turn battery disconnect switch to OFF
position (WP 0007). Remove one non-operating lower side warning light (WP 0351).
With a test lead set, check for continuity across main wire harness wire 1640 (black)
from main wire harness side warning light connector, terminal 1 to a known good
ground.
If there is no continuity, repair wire 1640 in main wire harness if repairable
(TM 9-2320-325-14&P), or replace main wire harness (WP 0455).
0155-10