0131
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03667
Step 55.
Disconnect main wire harness pump house power distribution wire harness connector
DP1. Check for continuity across pump house power distribution wire harness wire
2828 (red) from pump house power distribution wire harness connector DP1, terminals
16 and 18 to relay P10, terminal 87.
If there is no continuity at either terminal, repair wire 2828 in pump house
power distribution wire harness if repairable (TM 9-2320-325-14&P), or
replace pump house power distribution wire harness and block (WP 0457).