EQUIPMENT (LADDER) RACK DOES NOT OPERATE - Continued
EQUIPMENT (LADDER) RACK DOES NOT OPERATE - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  132    133    134    135    136  137  138    139    140    141    142  
img
DRAFT
TM 5-4210-249-13&P-2
0131
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03630
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 52.
Disconnect main wire harness pump house power distribution wire harness connector
DP1. With a test lead set, check for continuity across pump house power distribution
wire harness wire 1364 (white) from pump house power distribution wire harness
connector DP1, terminals 8 and 10 to relay P10, terminal 30.
If there is no continuity, repair wire 1364 in pump house power distribution
wire harness if repairable (TM 9-2320-325-14&P), or replace pump house
power distribution wire harness and block (WP 0457).