DRAFT
TM 5-4210-249-13&P-2
0131
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03651
Step 53.
Disconnect main wire harness crew cab wire harness connector. With a test lead set,
check for continuity across main wire harness wire 1364 (white) from main wire harness
pump house power distribution wire harness connector DP1, terminals 8 and 10 to main
wire harness crew cab wire harness connector, terminals E and S.
a.
If there is continuity across both wires 1364, repair wire 1364 in crew
cab wire harness if repairable (TM 9-2320-325-14&P), or replace crew
cab wire harness (WP 0446).
b.
If there is no continuity across either wire 1364, repair wire 1364 in
main wire harness if repairable (TM 9-2320-325-14&P), or replace
main wire harness (WP 0455).
0131-42