HYDRAULIC GENERATOR PTO DOES NOT ENGAGE WHEN SELECTED - Continued
WATER TANK DRAIN VALVE DOES NOT OPERATE WHEN SELECTED

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  985    986    987    988    989  990  991    992    993    994    995  
img
.
DRAFT
TM 5-4210-249-13&P-1
0121
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04327
Step 11.
Turn battery disconnect switch to OFF position (WP 0007). Disconnect cab power
distribution wire harness cab instrument panel wire harness connector. With a test lead
set, check for continuity across cab instrument panel wire harness connector wire 2700
(red) terminal 12, to cab instrument panel wire harness GENERATOR PTO switch
connector, terminal 6.
a.
If there is continuity, repair wire 2700 in cab power distribution wire
harness if repairable (TM 9-2320-325-14&P), or replace cab power
distribution wire harness and block (WP 0441).
b.
If there is no continuity, repair wire 2700 in cab instrument panel wire
harness if repairable (TM 9-2320-325-14&P), or replace cab instrument
panel wire harness (WP 0440).
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE