HYDRAULIC GENERATOR PTO DOES NOT ENGAGE WHEN SELECTED - Continued
HYDRAULIC GENERATOR PTO DOES NOT ENGAGE WHEN SELECTED - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  983    984    985    986    987  988  989    990    991    992    993  
img
DRAFT
TM 5-4210-249-13&P-1
0121
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04325
WARNING
ICON 15
Do not start engine during this procedure. Failure to comply may result in serious
injury or death to personnel.
Step 8.
Disconnect main wire harness PTO solenoid connector. With a test lead set, check for
continuity across wire 2162 (white) from cab instrument panel wire harness PTO switch
connector, terminal 5 to main wire harness PTO solenoid connector, terminal B.
If there is no continuity, go to Step 10.
Step 9.
Check for continuity across wire 1100 (black) from main wire harness PTO solenoid
connector, terminal A to a known good ground.
a.
If there is continuity, replace generator PTO solenoid (WP 0602).
b.
If there is no continuity, repair wire 1100 in main wire harness if
repairable (TM 9-2320-325-14&P), or replace main wire
harness (WP 0455).
0121-8