DRAFT
TM 5-4210-249-13&P-1
0120
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 8.
Put GROUND SWEEPS switch to off position (WP 0004). Turn battery disconnect
switch to OFF position (WP 0007). With a test lead set, check for continuity across wire
2200 (black) from valve control wire harness ground sweeps control valve connector,
terminal 2 to a known good ground.
a.
If there is continuity, replace ground sweeps control valve (WP 0375).
b.
If there is no continuity, repair wire 2200 in valve control wire harness if
repairable (TM 9-2320-325-14&P), or replace valve control wire
harness (WP 0463).
TFFT03534
Step 9.
Check if GROUND SWEEPS indicator is illuminated (WP 0004).
If GROUND SWEEPS indicator is not illuminated, go to Step 12.
0120-7