GROUND SWEEPS DO NOT OPERATE WHEN SELECTED - Continued
GROUND SWEEPS DO NOT OPERATE WHEN SELECTED - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  970    971    972    973    974  975  976    977    978    979    980  
img
. .
DRAFT
TM 5-4210-249-13&P-1
0120
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03536
Step 11.
Put GROUND SWEEPS switch to off position (WP 0004). Turn battery disconnect
switch to OFF position (WP 0007). Remove skid plate grille (WP 0550). Disconnect
main wire harness main 5 connector. With a test lead set, check for continuity across
main wire harness wire 2772 (gray) from main 5 connector, terminal 13 to main wire
harness valve control wire harness connector DV1, terminal 10.
a.
If there is continuity, repair wire 2772 in cab pump control wire harness
if repairable (TM 9-2320-325-14&P), or replace cab pump control wire
harness (WP 0443).
b.
If there is no continuity, repair wire 2772 in main wire harness if
repairable (TM 9-2320-325-14&P), or replace main wire
harness (WP 0455).