MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03529
Step 3.
Open pump house panel A (WP 0539). Inspect air lines from air control valve manifold
to ground sweeps nozzle valve for kinks and damage.
If air lines are kinked or damaged, replace damaged air lines (WP 0567).
TFFT03530
Step 4.
Turn battery disconnect switch to ON position (WP 0007). Put cab or pump operator's
panel TANK TO PUMP switch to OPEN position (WP 0004). Check if TANK TO PUMP
indicator illuminates.
If TANK TO PUMP indicator does not illuminate, go to Step 14.