DRAFT
TM 5-4210-249-13&P-1
0115
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04114
Step 29.
Turn battery disconnect switch to OFF position (WP 0007). Remove driver side crew
cab access panel (WP 0499). Remove pump house panel Q (WP 0325). Disconnect
pump operator's panel wire harness main wire harness connector DO 2. Check for
continuity across wire 2773 (red) from DRIVER MAIN INLET PRIMER switch to pump
operator's panel wire harness main wire harness connector DO 2, terminal 16.
a.
If continuity is present, replace pump operator's panel DRIVER MAIN
INLET PRIMER switch (WP 0333).
b.
If continuity is not present, repair wire 2773 in pump operator's panel
wire harness if repairable (TM 9-2320-325-14&P), or replace pump
operator's panel wire harness (WP 0459).
Step 30.
Prepare vehicle to pump from draft (WP 0025). Pull PUMP PRIMER manual primer
If water is not drawn to water pump, go to Step 40.
0115-18