PUMP PRIMING SYSTEM DOES NOT OPERATE PROPERLY - Continued
PUMP PRIMING SYSTEM DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  855    856    857    858    859  860  861    862    863    864    865  
img
. .
DRAFT
TM 5-4210-249-13&P-1
0115
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04109
Step 11.
While an assistant pushes and holds pump operator's panel DRIVER MAIN INLET
PRIMER switch (WP 0004), check for 22 to 28 VDC between pump house wire harness
wire 4067 (orange) at driver main inlet primer valve and a known good ground.
If 22 to 28 VDC are not present, go to Step 13.
Step 12.
Turn battery disconnect switch to OFF position (WP 0007). Disconnect pump house
wire harness wire 4068 (black) from driver main inlet primer valve terminal (WP 0268).
Check for continuity across wire 4068 (black) from wire termination to a known good
ground.
a.
If continuity is present, replace primer valve (WP 0268).
b.
If continuity is not present, repair wire 4068 in pump house wire
harness if repairable (TM 9-2320-325-14&P), or replace pump house
wire harness (WP 0458).
0115-9