DRAFT
TM 5-4210-249-13&P-1
0115
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04105
Step 5.
Disconnect cab pump control wire harness cab power distribution wire harness
connector. With a test lead set, check continuity across cab pump control wire harness
wire 2773 (red) from cab pump control wire harness cab PUMP PRIME switch
connector terminal 5, to cab pump control wire harness cab power distribution wire
harness connector, terminal 8.
If continuity is not present, repair wire 2773 in cab pump control wire
harness if repairable (TM 9-2320-325-14&P), or replace cab pump control
wire harness (WP 0443).
0115-5