PASSENGER SIDE AUXILIARY INLET VALVE DOES NOT OPERATE PROPERLY - Continued
PASSENGER SIDE AUXILIARY INLET VALVE DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  811    812    813    814    815  816  817    818    819    820    821  
img
. .
DRAFT
TM 5-4210-249-13&P-1
0113
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03442
NOTE
Do not engage water pump engine during this procedure. Valve operations can be
checked without water pump operations.
Valve motor operation can be checked either by noting vibration of valve assembly, or by
observing rotation of 7/16 in. hex at end of valve drive assembly worm gearshaft.
Do not remove cap from PASSENGER SIDE AUX. INLET. Water may be released from
the system when valve is operated.
Step 9.
Turn battery disconnect switch to ON position (WP 0007). While an assistant pushes
pump operator's panel PASSENGER SIDE AUX. INLET valve control OPEN and
CLOSE buttons (WP 0004), check if PASSENGER SIDE AUX. INLET valve control
THROTTLED (yellow) indicator illuminates and passenger side auxiliary inlet valve
motor operates.
If indicator illuminates and valve motor operates, replace passenger side
auxiliary inlet valve drive assembly (WP 0388).