NO. 3 DISCHARGE VALVE (PASSENGER SIDE) DOES NOT OPERATE PROPERLY - Continued
NO. 3 DISCHARGE VALVE (PASSENGER SIDE) DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  783    784    785    786    787  788  789    790    791    792    793  
img
DRAFT
TM 5-4210-249-13&P-1
0111
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT02666
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 15.
Remove No. 3 passenger side discharge valve pressure transducer (WP 0411).
Disconnect No. 3 passenger side discharge valve pressure transducer wire harness
from NO. 3 PASSENGER SIDE DISCHARGE valve control. Connect pressure
transducer to NO. 3 PASSENGER DISCHARGE valve control (removing wire harness
from circuit). Check if error message EPrL or EPrH is displayed.
a.
If EPrL or EPrH error message is displayed, replace No. 3 passenger
side valve discharge pressure transducer (WP 0411).
b.
If EPrL or EPrH error message is not displayed, repair pressure
transducer wire harness if repairable (TM 9-2320-325-14&P), or
replace No. 3 passenger side discharge valve pressure transducer wire
harness (WP 0460).
0111-13