• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
NO. 3 DISCHARGE VALVE (PASSENGER SIDE) DOES NOT OPERATE PROPERLY - Continued
NO. 3 DISCHARGE VALVE (PASSENGER SIDE) DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  782    783    784    785    786  787  788    789    790    791    792  
img
DRAFT
TM 5-4210-249-13&P-1
0111
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT02733
Step 13.
Remove four screws and bezel from pump operator's panel NO. 3 PASSENGER SIDE
DISCHARGE valve control. Check for signs of water and moisture damage.
If NO. 3 PASSENGER SIDE DISCHARGE valve control shows evidence of
water and moisture damage, replace NO. 3 PASSENGER SIDE
DISCHARGE valve control (WP 0417).
Step 14.
Install bezel and four screws on NO. 3 PASSENGER SIDE DISCHARGE valve control.
Remove No. 3 passenger side discharge valve (WP 0487) and inspect it for binding,
damage, and contamination.
a.
If No. 3 passenger side discharge valve is free from binding, damage,
and contamination, reinstall valve (WP 0487) and replace No. 3
passenger side discharge valve motor and drive assembly (WP 0388).
b.
If No. 3 passenger side discharge valve is binding, damaged, and/or
contaminated, replace No. 3 passenger side discharge valve
(WP 0487).
0111-12