DRIVER SIDE PRE-CONNECT B VALVE DOES NOT OPERATE PROPERLY - Continued
DRIVER SIDE PRE-CONNECT B VALVE DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  734    735    736    737    738  739  740    741    742    743    744  
img
. .
DRAFT
TM 5-4210-249-13&P-1
0108
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03857
Step 12.
Connect driver side pre-connect B valve control wire harness connector to driver side
pre-connect B valve motor. Disconnect No. 4 passenger side discharge valve control
wire harness connector from No. 4 passenger side discharge valve control. Turn
battery disconnect switch to ON position (WP 0007). Connect driver side pre-connect B
valve control wire harness connector to NO. 4 PASSENGER SIDE DISCHARGE valve
control. While an assistant pushes pump operator's panel NO. 4 PASSENGER SIDE
DISCHARGE valve control OPEN and CLOSE buttons (WP 0004), check if driver side
pre-connect B valve operates.
a.
If driver side pre-connect B valve operates, reconnect valve control
wire harness connectors to original positions and replace DRIVER
SIDE PRE-CONNECT B valve control (WP 0417).
b.
If driver side pre-connect B valve does not operate, reconnect valve
control wire harness connectors to original positions and replace driver
side pre-connect B valve motor (WP 0388).
0108-11