MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03859
Step 13.
Remove four screws and bezel from pump operator's panel DRIVER SIDE
PRE-CONNECT B valve control. Check for signs of water and moisture damage.
If DRIVER SIDE PRE-CONNECT B valve control shows evidence of water
and moisture damage, replace DRIVER SIDE PRE-CONNECT B valve
control (WP 0417).
Step 14.
Install bezel and four screws on DRIVER SIDE PRE-CONNECT B valve control.
Remove driver side pre-connect B valve (WP 0496) and inspect it for binding, damage,
and contamination.
a.
If driver side pre-connect B valve is free from binding, damage, and
contamination, reinstall valve (WP 0496) and replace driver side
pre-connect B valve motor and drive assembly (WP 0388).
b.
If driver side pre-connect B valve is binding, damaged, and/or
contaminated, replace driver side pre-connect B valve (WP 0496).