DRAFT
TM 5-4210-249-13&P-1
0102
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT02576
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 10.
Open pump operator's panel housing (WP 0325). Disconnect pump operator's panel
wire harness FOAM A LEVEL gauge connector. With a test lead set, check for 22 to 28
VDC between wire 2342 (red) at pump operator's panel wire harness FOAM A LEVEL
gauge connector, terminal 1 and a known good ground.
If 22 to 28 VDC are not present, repair wire 2342 in pump operator's panel
wire harness if repairable (TM 9-2320-325-14&P), or replace pump
operator's panel wire harness (WP 0459).
Step 11.
Turn battery disconnect switch to OFF position (WP 0007). With a test lead set, check
for continuity across pump operator's panel wire harness wire 3895 (black) from pump
operator's panel wire harness FOAM A LEVEL gauge connector, terminal 2 to a known
good ground.
a.
If there is continuity, replace pump operator's panel FOAM A LEVEL
gauge (WP 0322).
b.
If there is no continuity, repair wire 3895 in pump operator's panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator's panel wire harness (WP 0459).
0102-7