DRAFT
TM 5-4210-249-13&P-1
0102
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT02575
Step 7.
Turn battery disconnect switch to OFF position (WP 0007). Open pump operator's
panel housing (WP 0325). Disconnect cab water level gauge wire harness connector
from pump operator's panel FOAM A LEVEL gauge. Remove cab instrument panel A
(WP 0311). Disconnect cab foam level gauge wire harness connector from cab FOAM
A LEVEL gauge. With a test lead set, check for continuity across cab foam level gauge
wire harness from pump operator's panel FOAM A LEVEL gauge connector, terminal 1
to cab FOAM A LEVEL gauge connector, terminal 1. Note reading. Repeat continuity
checks for terminals 2 to 2, 3 to 3, 4 to 4, 5 to 5, 6 to 6, and 7 to 7.
a.
If there is continuity across all terminals of cab foam level gauge wire
harness, replace cab FOAM A LEVEL gauge (WP 0316).
b.
If there is no continuity for any pair of terminals, replace cab foam level
gauge wire harness (WP 0439).
0102-5