FOAM NOT DELIVERED FROM ROOF TURRET - Continued
FOAM NOT DELIVERED FROM ROOF TURRET - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  548    549    550    551    552  553  554    555    556    557    558  
img
. .
DRAFT
TM 5-4210-249-13&P-1
0098
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03500
Step 12.
Push and release roof turret agent discharge button (WP 0004). Turn battery
disconnect switch to OFF position (WP 0004). With a test lead set, check for continuity
across wire 2200 (black) from valve control wire harness roof turret foam B foam
system flow control manifold connector, terminal 2 to a known good ground.
a.
If there is continuity, replace ROOF TURRET FOAM B metering control
valve (WP 0288).
b.
If there is no continuity, repair wire 2200 in valve control wire harness if
repairable (TM 9-2320-325-14&P), or replace valve control wire
harness (WP 0463).