CHECK PUMP ENGINE LIGHT COMES ON
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
References
Equipment Conditions
WP 0186
Engine OFF (TM 9-2320-347-10)
Wheels chocked (TM 9-2320-347-10)
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
CHECK PUMP ENGINE LIGHT COMES ON
TFFT04079A
Step 1.
Check water pump engine cooling air vents for blockage.
If pump engine cooling air vents are blocked, clear blockage.
0053-1