FOAM SYSTEM OPERATING PROCEDURES (CAB INSTRUMENT PANEL) - Continued
BUMPER TURRET OPERATION - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  142    143    144    145    146  147  148    149    150    151    152  
img
.
DRAFT
TM 5-4210-249-13&P-1
0035
OPERATOR MAINTENANCE
BUMPER TURRET OPERATION
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT02217
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 72
Turret should never be pointed at personnel. Failure to comply may result in injury
or death to personnel.
NOTE
Bumper turret is controlled from inside personnel cab by using joystick control box.
1.
Lift power switch guard (1) and put power switch (2) to | (on) position. Indicator light (3) will illuminate.
2.
Push and release agent discharge button (4) on front of joystick control handle (5) to begin discharge.
NOTE
Pattern control button, located on top of joystick, controls nozzle discharge pattern.
Pressing switch to left changes nozzle pattern to fog pattern. Pressing switch to right
changes nozzle pattern to straight stream.
3.
Press pattern control button (6) to desired pattern.