DRAFT
TM 5-4210-249-13&P-1
0032
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT02615
6.
Make sure TANK FILL & RE-CIRCULATING LINE valve control (1) is in CLOSED position. Red indicator
light (2) will illuminate.
7.
Put pump operator's panel PUMP COOLER switch (3) to OFF position. Indicator light (4) will go out.
8.
Put cab RECIRC LINE switch (5) to OFF position. Indicator light (6) will go out.
END OF TASK
FOAM SYSTEM-STANDBY MODE
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 5, 66
Open and close all valves slowly during any procedure. Sudden changes in
pressure may cause equipment to react faster than personnel can be alerted.
Ensure surrounding personnel are aware of changes being made to settings on
equipment. Failure to comply may result in serious injury or death to personnel and
damage to equipment.
CAUTION
Turn on foam system only when needed. Failure to comply may result in damage to
equipment.
NOTE
When in foam mode, never open TANK FILL & RE-CIRCULATING LINE valve. This will
cause foam agent to enter water tank. If recirculation is needed to keep pump cool, open
PUMP COOLER valve.
Foam system is in Standby Mode when:
1.
0032-2