FOAM AGENT FILLING/DRAINING/FLUSHING - Continued
FOAM SYSTEM AND INSTRUMENT PANEL-STANDBY MODE

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  131    132    133    134    135  136  137    138    139    140    141  
img
. .
DRAFT
TM 5-4210-249-13&P-1
0031
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT04375
NOTE
Local draining laws must be followed when draining and flushing foam and water from
foam tanks.
10. Put FOAM TANK DRAIN valve (4) in open position and drain water from foam tank (5).
11. Repeat Steps (6) through (10) until foam tank (5) is clean.
12. Put FOAM TANK DRAIN valve (4) in closed position.
13. Put foam METERING VALVE (7) in open position.
14. Run foam system with water instead of foam (WP 0033).
15. Discharge water until foam tank (5) is empty.
16. All debris must be removed from foam tank (5) after flushing in complete.
TFFT04476
17. Close expansion dome (3).
18. Stow passenger side rear access ladder (WP 0013).
END OF TASK
END OF WORK PACKAGE