PRIMING WATER PUMP - Continued
PRIMING WATER PUMP - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  104    105    106    107    108  109  110    111    112    113    114  
img
DRAFT
TM 5-4210-249-13&P-1
0023
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT02105P
NOTE
Perform Steps (8) and (9) if/when driver's main inlet needs to be primed.
Priming the driver's main inlet allows pumping operation to continue uninterrupted by
pumping water from a draft when original pumping operations started from onboard water
tank.
Valve is completely closed when red indicator light illuminates.
8.
Push DRIVER MAIN INLET valve control CLOSE button (6) until red indicator light (7) illuminates.
9.
Push DRIVER MAIN INLET PRIMER switch (8) to prime driver main inlet.
NOTE
Perform Step (10) if driver's main inlet primer solenoid fails.
10. Pull MANUAL PRIMER handle (9) and push DRIVER MAIN INLET PRIMER switch (8).
0023-3