STARTING/STOPPING WATER PUMP ENGINE (CAB INSTRUMENT PANEL AND PUMP OPERATOR'S PANEL)
STARTING/STOPPING WATER PUMP ENGINE (CAB INSTRUMENT PANEL AND PUMP OPERATOR'S PANEL) - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  99    100    101    102    103  104  105    106    107    108    109  
img
.
DRAFT
TM 5-4210-249-13&P-1
0022
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - )
TFFT02190
CAUTION
If water pump engine fails to start, wait 15 seconds prior to next start attempt to
allow starter to cool. Do not turn ignition switch to START position while water
pump engine is rotating. Failure to comply may result in damage to equipment.
NOTE
If water pump engine fails to start, return engine switch to OFF position before attempting
to re-start.
4.
Put START PUMP STOP switch (3) or PUMP ENGINE switch (4) to START position. Indicator light (5) or (6)
will illuminate.
5.
Prime water pump (WP 0023).
0022-2