Pump Operator's Panel - Upper Center (Sheet 2 of 2).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Key
Control or Indicator
Function
Fig. 12
6
WATER TANK DRAIN Switch
Push switch to right to open tank drain. Push switch to left to close
tank drain.
7
TANK DRAIN Indicator Light
Illuminates when tank drain is open.
8
Warning Buzzer
Provides audible warning in the event of a water pump overheat
condition.
9
Thermal Relief Indicator Light
Illuminates in the event of a water pump overheat condition.
10
Warning Buzzer and Thermal
When depressed, checks operation of both warning buzzer and
Relief Indicator Light Test Button
thermal relief indicator light.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -