DRAFT
TM 5-4210-249-13&P-1
0004
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00029AP
Figure 4.
Cab Instrument Panel - Lower Center (Sheet 2 of 2).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Key
Control or Indicator
Function
Fig. 4
6
PUMP COOLER Switch
Push up to open valve to dump water to ground. Push down to
close valve. This helps keep water pump cool when water is not
being discharged.
7
PUMP COOLER Indicator Light
Indicator light illuminates when pump cooler valve is open.
8
Class A Foam Indicator Light
Indicator light illuminates when Class A foam is selected.
9
Class B Foam Indicator Light
Indicator light illuminates when Class B foam is selected.
10
FOAM SELECT Switch
Push switch to left for Class A foam; push switch to right for
Class B foam. Switch automatically goes to center position when
released.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0004-5