Figure 3. Cab Instrument Panel - Upper Center
ure 4. Cab Instrument Panel - Lower Center (Sheet 2 of 2)

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  23    24    25    26    27  28  29    30    31    32    33  
img
.
DRAFT
TM 5-4210-249-13&P-1
0004
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00029P
Figure 4.
Cab Instrument Panel - Lower Center (Sheet 1 of 2).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Key
Control or Indicator
Function
Fig. 4
1
START PUMP STOP Switch
Push up to start water pump engine. Push down to stop water
pump engine.
2
PUMP RUNNING Indicator Light
PUMP RUNNING indicator light illuminates when water pump is
running.
3
TANK TO PUMP Switch
Push up to open tank discharge (TANK TO PUMP) valve. Push
down to close tank discharge (TANK TO PUMP) valve.
4
TANK TO PUMP Indicator Light
Illuminates when tank discharge (TANK TO PUMP) valve is open.
5
PUMP PRIME Switch
Push up to activate priming valve and operate electric primer
pump. Release to close priming valve and stop electric primer
pump.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -